Face Mask Quality Control Inspection Services for medical and non-surgical

At the time of the pandemic, outbreak, there were many the fraud traders and the quality poor face masks are also chaotic in the market that is you need to have the face mask quality control inspection services.

People use the face masks for a multiple of purposes, but the main role is to protect the wearer.

In visual and laboratory,AIM Control (AIM Group®) face masks quality inspection services are used for

  • in surgeries

  • non-surgical

Face-Mask-Quality-Control-Inspection-Services

Some stage of AIM’s face masks quality control inspection services

  • The materials are sample for test the specification which used to production of face masks

  • Face Masks Quality control period of production

  • Verifying final random AQL face masks quality inspection

  • Witness of tests of specification at the supplier’s factory

  • Pre-shipment and face masks package of inspection

  • Number counting of face masks in carton

  • Quantity tally of face masks (carton to carton)

  • Loading supervision

  • Pre delivery Inspection

  • Report and certification

There are various items of face masks in manufacturing and trading

  • Class type and size

  • Specialized type

  • Quality

  • Standard

  • Disposable

  • Antimicrobial

face-mask-quality-control-inspection-certification

QA/QC

Ply Masks (03 or 04 layers)

Particle filtering a half masks are classified according to their filtering efficiency and maximum total inward leakage, there are three or four classes devices

  • FFP1

  • FFP2

  • FFP3

  • FFP4

AIM-Face-Mask-Quality-Control-Inspection-organization

Particle filtering a half masks meeting the requirement of European standards EN 149:2001 + A1:2009 FFP2 NR

  • Tests and inspection

  • Testing all of samples

  • Nominal values tolerances

  • Visual inspection

  • Packaging (protected against mechanical damage and contamination)

face-mask-quality-control-and-inspection-certificate

Material (materials used shall suitable to withstand handling and wear over the period for which the particle filtering half mask is designed to be used. Any material from filter media released by the air flow through the filter shall not constitute a hazard or nuisance for the wearer).

Cleaning and disinfecting (if the particle filtering half mask is designed to be reusable, the materials used shall withstand the cleaning and disinfecting agents and procedure to be specified by manufacturer)

Practical performance (the particle filtering half mask shall undergo practical performance tests under realistic conditions

Finish of parts (come into contact with the wearer shall have no sharp edges or burrs)

Leakage (Total inward leakage, penetration of filter material)

Compatibility with shin (materials that may come into contact with the wearer’s skin shall not be known to be likely to cause irritation or any other adverse effect to health)

Flammability (the material used shall not present a danger for the wearer and shall not be of highly flammable nature)

Carbon dioxide content of the inhalation air (dead space shall not exceed an average of 1.0% (by volume)  

Head harmless (shall be designed can be donned and removed easily and adjustable or self-adjusting and sufficiency robust to hold the particle)

Field of vision (Field of vision is acceptable in practical performance tests)

Exhalation valve (s)

  • a partial filtering half mask may have one or more exhalation valves and shall function correctly in all orientations

  • Exhalation valve is provided if shall be protected against or be resistant to dirt and mechanical damage and may be shrouded or may include any other device

  • Exhalation valve (s) shall continue to operate correctly after a continuous exhalation flow of 300 l/min over a period of 30s.

  • Exhalation valve housing is attached to face-blank and withstand axially a tensile force of 10N applied for 10s 

face-mask-quality-control-inspection-certification-company

Breathing resistance (Breathing resistance apply to valved and valveless and shall meet the requirement

Clogging

  • for single – use devices clogging test is an optional test

  • devices designed to be resistant to clogging, show by a slow increase

  • the specified breathing resistances shall not be exceeded before the required dust load of 833 mg h/m3

  • Breathing resistance (valveless and valved particle filtering half masks)

  • Penetration of filtering half masks (all types claimed to meet the clogging requirement shall also meet the penetration requirements given above mentioned)

Demountable parts (all Demountable parts if filtering shall be readily connected anbsd secured, where possible by hands)

Visual inspection  (is carried out appropriate by AIM Control (AIM Group®) inspector at the site prior to laboratory or practical performance tests

Conditioning

  • Simulated

    • wearing treatment (a breathing machine is adjusted 25 cycles/min and 2.0 l/stroke
    • For testing a saturator is incorporated in the exhalation line between the breathing machine and the mummy head
    • The spilling out of the dummy’s mouth and contaminating the particle filtering half mask the head shall be incline
  • Temperature conditioning

Marking

Packaging

Face-Masks-Quality-Control-Inspection-services

Contact us


Written : @AIMGroup
Show
Filter by
Enter keyword
Activity
Online support
Hotline : +84888889879
Cell : +84 903 615 612
Email : aim@aimcontrolgroup.com
Skype :
Field
Worldwide Inspection Services Vietnam (H.O)